1. Overview:
This is an indoor use pure RLC load bank LB-640KVA-AC400V-J.
The load testing system is composed of two parts: the loads and the control system, which mainly include alloy resistors, shunt reactors, capacitors, gear contactors, PLC, protection system, heat dissipation device, auxiliary control. All the elements are packaged in an enclosure, can be used indoor and outdoor.
Working Environment:
|
Ambient Temperature : |
-10℃ to +45℃ |
|
Relative Humidity: |
monthly less than 90%, daily less than 95%(25℃) |
|
Altitude: |
≤1000m |
|
Service location: |
indoor, vertically installed, the inclined degree less than 5 degrees |
Technical Parameters
|
No. |
Item |
Description |
|
1 |
Model |
LB-640KVA-AC400V-J |
|
2 |
Type |
RLC(PF=0.8) |
|
3 |
Capacity |
640KVA |
|
4 |
Rated Voltage |
AC400V |
|
5 |
Control Mode |
Local manual control, and remote control via laptop |
|
6 |
Resistance Tolerance |
≤±3% |
|
7 |
Data Acquisition Accuracy |
0.5 |
|
8 |
Working Method |
continuous |
|
9 |
Dimension |
1800*1800*2000mm (W*D*H) |
|
10 |
Ingress Protection |
IP20 when working, IP54 when in storage condition |
|
11 |
Cooling Method |
Forced air cooling (air in from side, out from side) |
|
12 |
Auxiliary Power Supply |
AC400V 50Hz, 3P4W, 10KW |
|
13 |
Service Location |
Indoor |
|
14 |
Cable Incoming/Outgoing |
From bottom |
|
15 |
Power Frequency Withstand Voltage |
5000V(1Min.), no breakdown, no arcing |
|
16 |
Insulation Resistance |
≥2MΩ(1000V) |
|
17 |
Weight |
About 650KG |
|
18 |
Color |
RAL7035 |


Hot Tags: 640kva resistive/inductive/capacitive rlc load bank, China, manufacturers, suppliers, factory, customized, price, made in China, Load Bank 100KW, AC DC Load Bank, 500KW Load Bank, 1MW Load Bank, 1000KW Resistive Load Bank, Battery Test Load Bank