Neutral Grounding Transformer And Resistor

Neutral Grounding Transformer And Resistor
Details:
35KV 400A IP00 50.5R without enclosure
Send Inquiry
Download
Description
Technical Parameters

Neutral Grounding Transformer And Resistor Descriptions:

Because of the fact that the fault currents at star point grounded mains should be limited, transformers/generators are grounded over star point 

with neutral grounding resistors. In this way earth fault could be sensed by protection relays while limiting the current damage. Our neutral grounding 

resistors could be manufactured at desired power and resistance values for transformer substations, wind power stations and generator application.

• Resistor component are manufactured from AISI 304 alloy stainless steel sheet.
• There is no contrivance for zipping with micanite in order to contact routes of the resistors on plates.
• Resistor plates are mounted with steatite porcelain material.
• During transportion, there is no damage on the steatite bindings for resistor plates even on the rugged roads.

• Because of using steatite material instead of micanite, the resistors would not be damaged and would be ready for function even after the increase of fault 

   current and the increase of the temperature due to delay of the function of the relays.

• The voltage and eye control test and the observation of any damage of the isolated parts can be done easily with two doors design of the construction of the 

   Neutral Grounding Resistor.

• The enclosure of the Neutral Grounding Resistor is made of the hot dip galvanized steel sheet instead of galvanized steel sheet.

neutral grounding transformer and resistor 01

Advantages of Fullde Neutral Grounding Resistor:

1. The standard size of the switchgear design is beautiful, and the overall fit of the customer's field equipment.
2. Adopt high-quality nickel-chromium alloy resistance sheet, high power density, low temperature coefficient, good corrosion resistance.
3. Non-inductive processing technology to prevent eddy current inside the resistor.
4. Configure the transformer recorder, etc., the resistor can record the running status and provide remote monitoring function.
5. The resistance core adopts double insulation design to meet the fault current impact and maintain the insulation performance of the resistor.

Details of NGR


Drawings of Neutral Grounding Transformer And Resistor :

neutral grounding transformer and resistor 02

详情页压缩后


Fullde customer reference

Fullde Exhibitions

Company Introduction





 

Hot Tags: neutral grounding transformer and resistor, China, manufacturers, suppliers, factory, customized, price, made in China, 11kv neutral earthing resistor, General Electric Neutral Grounding Resistor, neutral grounding resistor for transformers, neutral earthing resistor testing, Neutral Grounding Resistor, neutral earthing resistor for transformer